Title: “Over-SIRIX”: un nuovo metodo per calcolare l’oversizing delle endoprotesi utilizzando “OsiriX Imaging Software”. Esperienza preliminare nell’impiego di “chimney technique” dell’arco aortico
Other Titles: “Over-SIRIX”: a new method to calculate endograft oversizing by using “OsiriX Imaging Software”. Early experience with chimney technique and TEVAR for the aortic arch diseases
Authors: FAZZINI, STEFANO
Tutor: MARTINELLI, OMBRELLA
MANGIALARDI, NICOLA
Keywords: CHIMNEY TECHNIQUE
OVERSIZING
TEVAR
CHIMPS
GUTTERS
OVER-SIRIX
Issue Date: 23-Oct-2014
Abstract: “Over-SIRIX”: a new method to calculate endograft oversizing by using “OsiriX Imaging Software”. Early experience with chimney technique and TEVAR for the aortic arch diseases Stefano Fazzini, Vittorio Alberti, Sonia Ronchey, Eugenia Serrao, Nicola Mangialardi SAN FILIPPO NERI HOSPITAL, ROME, ITALY STUDY AND PURPOSE The aim of this study is to apply the "Over-SIRIX", a new method to measure oversizing for CHIMPS, not a standard formula. The intention is to minimize the maximum risk of type IA endoleaks, often coming from the gutters. METHOD AND SOURCES From 2002 to 2014 were treated 31 patients with CHIMPS for aortic arch. 19 patients with antegrade single chimney were included, and divided in two groups (PRE/POST) with retrospective and prospective study. The method consists in the study of the proximal neck (MPR), exactly at the level of chimney-graft complex, drawing a circle/oval representing the stent and the perimeter of the endoprosthesis in order to eliminate the "gutters". RESULTS: The average ideal oversizing was of 19.57% (11.4% -27%) and Over-SIRIX 13%; the area of the gutters (cut-off:0.75 cm2) decreased from 0.74 to 0.15 (PRE/POST) and the rate of endoleaks from 28.5% to 0% (PRE/POST). The average neck (26 mm) was comparable between the groups PRE/POST (27/23 mm). CONCLUSION: Over-SIRIX appears to be a simple method that can customize oversizing for CHIMPS reducing the risk of endoleak IA, which is related significantly to the presence and size of the gutters.
URI: http://hdl.handle.net/10805/2677
Research interests: HOW TO IMPROVE AN OFF-LABEL USE OF A MODERN ENDOVASCULAR TECHNIQUE
Skills short description: ADVANCED ENDOVASCULAR PLANNING OF THE MOST DIFFICULT AORTIC DISEASES
Personal skills keywords: CHIMNEY TECHNIQUE
CHIMPS
TEVAR
EVAR
ENDOLEAK
Appears in PhD:FISIOPATOLOGIA CHIRURGICA ANGIO-CARDIO-TORACICA E IMAGING FUNZIONALE RADIOISOTOPICO

Files in This Item:

File Description SizeFormat
TESI FINALE (corretta:PADIS).pdfTesi di dottorato17.68 MBAdobe PDF


This item is protected by original copyright

Recommend this item

Items in PADIS are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2010  Duraspace - Feedback Sviluppo e manutenzione a cura del CINECA